Deployment

Appliance hardware spec, network requirements, IT onboarding checklist, and installation timeline.

Capped AI ships a pre-configured 1U appliance. Your IT team needs 4 hours and three inputs: power, a network port, and an OPC-UA endpoint URL. Capped AI handles the rest.

Appliance hardware

ComponentSpecification
Form factor1U rack-mount server (Supermicro SYS-121H-TNR or equivalent)
CPUIntel Xeon Gold 6438N (32-core, 2.0 GHz base)
GPU2× NVIDIA H100 80GB SXM5 (NVLink bridge)
RAM256 GB DDR5 ECC registered
Storage (data)8 TB NVMe RAID-1 (handover WORM log, historian cache, pgvector)
Storage (OS)2 TB NVMe SSD (Ubuntu 22.04 LTS, software)
Network2× 10GbE SFP+ (OPC-UA + operator tablets), 1× 1GbE IPMI out-of-band
PowerDual 2200W PSU, 220V / 15A circuit required
Dimensions1U × 17.2″ × 28.0″ (H × W × D)
Weight~28 kg (62 lb) — standard pallet shipping
Operating temperature10–35°C (50–95°F)

Network requirements

ConnectionProtocolPortDirection
DCS historianOPC-UATCP 4840Appliance → DCS (inbound to DCS)
Operator tabletsHTTPSTCP 443Tablets → Appliance
Capped AI Ops Cloud (heartbeat)HTTPSTCP 443Appliance → cloud (outbound only)
IT management (optional)SSH over VPNTCP 22IT → Appliance (on-demand only)

No inbound connections from the internet are required or accepted. The appliance does not expose any public-facing services. All internet access is outbound-only (Capped AI Ops Cloud heartbeat). This outbound connection can be disabled entirely on request (fully air-gapped mode).

IT onboarding checklist

  • Confirm 1U rack space availability in control room or server room
  • Confirm dual 220V / 15A power circuits (redundant PSU)
  • Confirm 10GbE switch port reserved for appliance
  • Identify static IP address for appliance (or DHCP reservation)
  • Identify OPC-UA endpoint URL for DCS historian
  • Confirm OPC-UA credentials (username/password or certificate) for read-only session
  • Firewall rule: allow TCP 4840 from Capped AI appliance IP to DCS historian IP
  • Firewall rule: allow TCP 443 from operator tablet IPs to Capped AI appliance IP
  • Firewall rule: allow TCP 443 outbound from appliance to ops.capped.ai (heartbeat)
  • Coordinate IT contact for Capped AI field engineer visit (typically 1 day on-site)

On-site installation timeline

ActivityTimeWho
Unbox and rack the appliance1 hourCapped AI field engineer + IT team
Power-on and hardware verification30 minutesCapped AI field engineer
Network configuration (static IP, VLANs)1 hourIT team + Capped AI
OPC-UA historian connection and tag verification2 hoursCapped AI + DCS engineer
Operator tablet enrollment (HTTPS certificates)1 hourIT team
Smoke test — end-to-end handover generation1 hourCapped AI + shift supervisor
IT sign-off and documentation handover1 hourAll

Software update process

Capped AI delivers software updates (LLM patches, UI updates, bug fixes) via a signed package delivered to the appliance management endpoint. Updates follow this process:

  • Capped AI Ops Cloud notifies your IT contact of an available update with release notes
  • Your IT admin approves the update via the Capped AI admin dashboard
  • Appliance downloads and verifies the signed package (SHA-256 + ed25519 signature)
  • Update is applied during the next maintenance window (configurable, default: 02:00–04:00 local time)
  • Rollback to previous version available within 48 hours of any update

Hardware replacement

In the event of a hardware failure (GPU, disk, power supply), Capped AI ships a replacement component or full appliance within 5 business days (Standard tier) or 48 hours (Enterprise tier). Handover data is recoverable from the RAID-1 mirror or from the encrypted backup maintained on a secondary drive. Contact hello@capped.ai to report a hardware fault.